Double-wall chimney system DK-1M

 

Application
System is designated to exhaust combustion products by natural draught from heating appliances.
Combustible
Oil (except fuel, which sulfur content is ≥ 0.2% of weight), gas, solid fuels (except coal and peat)
Working temperature
≤ 600 °C
Steel
inner pipe: stainless steel 1.4301
Outer pipe: stainless steel 1.4301, galvanized tin or colored galvanized tin
Wall thickness
when dn from 80 to 200 mm - 0.5, 0.6, 0.8, 1.0 mm
when dn from 230 to 550 mm - 0.6, 0.8, 1.0 mm
when dn from 600 to 900 mm - 0.8, 1.0 mm
Insulation
Mineral insulation, thickness - 50 mm
Pressure class
N1 - natural draught
Sootfire resistance
G - resistant
Distance to combustible materials
≥ 1001 mm
Condensate resistance
D - designated for dry operating conditions
Certificate no.
1397-CPD-0183
1397-CPD-0184
Designation code
T600-N1-D-Vm-L20050-G100
T600-N1-D-Vm-L20060-G100
T600-N1-D-Vm-L20080-G100
T600-N1-D-Vm-L20100-G100

 

 

Copyright 2011 Double-wall chimney system DK-1M. All Rights Reserved.