Application System is designated to exhaust combustion products by natural draught from heating appliances. Combustible Oil (except fuel, which sulfur content is ≥ 0.2% of weight), gas, solid fuels (except coal and peat) Working temperature ≤ 600 °C Steel inner pipe: stainless steel 1.4301 Outer pipe: stainless steel 1.4301, galvanized tin or colored galvanized tin Wall thickness when dn from 80 to 200 mm - 0.5, 0.6, 0.8, 1.0 mm when dn from 230 to 550 mm - 0.6, 0.8, 1.0 mm when dn from 600 to 900 mm - 0.8, 1.0 mm Insulation Mineral insulation, thickness - 50 mm Pressure class N1 - natural draught Sootfire resistance G - resistant Distance to combustible materials ≥ 1001 mm Condensate resistance D - designated for dry operating conditions Certificate no. 1397-CPD-0183 1397-CPD-0184 Designation code T600-N1-D-Vm-L20050-G100 T600-N1-D-Vm-L20060-G100 T600-N1-D-Vm-L20080-G100 T600-N1-D-Vm-L20100-G100
|
|